Disky jsou tiche a nevydavaji zadne zvuky, ktere by nemely. Prikladam kompletni SMART
smartctl 5.41 2011-06-09 r3365 [i686-linux-3.0.0-12-generic] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus Device Model: ST3120026A Serial Number: 3LJ041Q1 Firmware Version: 3.01 User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 2 Local Time is: Sun Nov 20 21:20:13 2011 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 065 059 006 Pre-fail Always - 95472666 3 Spin_Up_Time 0x0003 096 096 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 38 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 075 060 030 Pre-fail Always - 112552628733 9 Power_On_Hours 0x0032 031 031 000 Old_age Always - 61065 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 57 194 Temperature_Celsius 0x0022 022 057 000 Old_age Always - 22 195 Hardware_ECC_Recovered 0x001a 065 059 000 Old_age Always - 95472666 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 58480 - # 2 Short offline Completed without error 00% 58457 - # 3 Extended offline Completed without error 00% 58435 - # 4 Short offline Completed without error 00% 58433 - # 5 Short offline Completed without error 00% 58410 - # 6 Short offline Completed without error 00% 58386 - # 7 Short offline Completed without error 00% 58363 - # 8 Short offline Completed without error 00% 58339 - # 9 Short offline Completed without error 00% 58315 - #10 Short offline Completed without error 00% 58292 - #11 Extended offline Completed without error 00% 58270 - #12 Short offline Completed without error 00% 58268 - #13 Short offline Completed without error 00% 58245 - #14 Short offline Completed without error 00% 58221 - #15 Short offline Completed without error 00% 58198 - #16 Short offline Completed without error 00% 58174 - #17 Short offline Completed without error 00% 58151 - #18 Short offline Completed without error 00% 58127 - #19 Extended offline Completed without error 00% 58105 - #20 Short offline Completed without error 00% 58103 - #21 Short offline Completed without error 00% 58080 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
Nelekejte se tech vysokych hodnot 1, 7, 195. Je to u techte Seagatu normalni. Pokud jsou hodnoty 1 a 195 stejne, tak je to OK.
ISSN 1214-1267, (c) 1999-2007 Stickfish s.r.o.