Portál AbcLinuxu, 19. prosince 2025 21:41
| Ovladač: | v jádře |
IBM DeskStar 40GV family 80418240 sectors (41174 MB) w/380KiB Cache, CHS=79780/16/63, UDMA(44), 5400RPMhttp://www.storage.ibm.com/hdd/desk/ds40gv.htm
hdparm -i /dev/hda:
Model=IBM-DTLA-305040, FwRev=TW4OA60A, SerialNo=YJEYJ0Q2910
Config={ HardSect NotMFM HdSw>15uSec Fixed DTR>10Mbs }
RawCHS=16383/16/63, TrkSize=0, SectSize=0, ECCbytes=40
BuffType=DualPortCache, BuffSize=380kB, MaxMultSect=16, MultSect=16
CurCHS=16383/16/63, CurSects=16514064, LBA=yes, LBAsects=80418240
IORDY=on/off, tPIO={min:240,w/IORDY:120}, tDMA={min:120,rec:120}
PIO modes: pio0 pio1 pio2 pio3 pio4
DMA modes: mdma0 mdma1 mdma2 udma0 udma1 udma2 *udma3 udma4 udma5
AdvancedPM=yes: disabled (255) WriteCache=enabled
Drive Supports : ATA/ATAPI-5 T13 1321D revision 1 : ATA-2 ATA-3 ATA-4 ATA-5
hdparm -I /dev/hda:
non-removable ATA device, with non-removable media
powers-up in standby; SET FEATURES subcmd spins-up.
WARNING: ID response incomplete.
WARNING: Following data may be incorrect.
Model Number: IBM-DTLA-305040
Serial Number: YJEYJ0Q2910
Firmware Revision: TW4OA60A
Standards:
Used: ATA/ATAPI-5 T13 1321D revision 1
Supported: 2 3 4 5
Configuration:
Logical max current
cylinders 16383 16383
heads 16 16
sectors/track 63 63
bytes/track: 0 (obsolete)
bytes/sector: 0 (obsolete)
current sector capacity: 16514064
LBA user addressable sectors = 80418240
Capabilities:
LBA, IORDY(can be disabled)
Buffer size: 380.0kB ECC bytes: 40 Queue depth: 32
Standby timer values: spec'd by standard, no device specific minimum
r/w multiple sector transfer: Max = 16 Current = 16
DMA: mdma0 mdma1 mdma2 udma0 udma1 udma2 *udma3 udma4 udma5
Cycle time: min=120ns recommended=120ns
PIO: pio0 pio1 pio2 pio3 pio4
Cycle time: no flow control=240ns IORDY flow control=120ns
Commands/features:
Enabled Supported:
* NOP cmd
* READ BUFFER cmd
* WRITE BUFFER cmd
* Host Protected Area feature set
release interrupt
* look-ahead
* write cache
* Power Management feature set
Security Mode feature set
SMART feature set
SET MAX security extension
Address offset used (large drive)
SET FEATURES subcommand required to spinup after power up
Power-Up In Standby feature set
Advanced Power Management feature set
* READ/WRITE DMA QUEUED
Security:
Master password revision code = 65534
supported
not enabled
not locked
not frozen
not expired: security count
not supported: enhanced erase
42min for SECURITY ERASE UNIT.
HW reset results:
CBLID- above Vih
Device num = 0 determined by the jumper
Checksum: correct
Dokument vytvořil: Petr Slansky, 5.6.2002 00:55 | Zobrazeno: 892×
Tiskni
Sdílej: