Portál AbcLinuxu, 10. května 2025 20:37

Areca ARC-1200

Podpora: kompletní
Ovladač: v jádře
Adresa ovladače: ftp://ftp.unnet.nl/pub/areca/RaidCards/AP_Driver..

Technické parametry

2-Port SATA II
PCIe x1
RAID Level Support: 0, 1, Single Disk and JBOD
Cache Memory: 128MB
Internal Disk Connector : 2*SATA
External Disk Connector : N/A

Identifikace pod Linuxem

ARECA RAID ADAPTER10: FIRMWARE VERSION V1.43 2007-10-31 
scsi10 : Areca SATA Host Adapter RAID Controller (.......)
 Driver Version 1.20.00.15 2007/08/30
scsi 10:0:0:0: Direct-Access     Areca    ARC-1200-VOL#00  R001 PQ: 0 ANSI: 5
.
.
sd 10:0:0:0: [sdb] Attached SCSI disk
sd 10:0:0:0: Attached scsi generic sg3 type 0
scsi 10:0:16:0: Processor         Areca    RAID controller  R001 PQ: 0 ANSI: 0
scsi 10:0:16:0: Attached scsi generic sg4 type 3

[10:0:0:0]   disk    Areca    ARC-1200-VOL#00  R001  /dev/sdb
[10:0:16:0]  process Areca    RAID controller  R001  -       

03:00.0 RAID bus controller: Areca Technology Corp. Device 1201
        Subsystem: Areca Technology Corp. Device 1200
        Flags: bus master, fast devsel, latency 0, IRQ 16
        Memory at de000000 (64-bit, prefetchable) [size=1M]
        Memory at de100000 (64-bit, prefetchable) [size=64K]
        Memory at de110000 (64-bit, prefetchable) [size=64K]
        [virtual] Expansion ROM at de180000 [disabled] [size=512K]
        Capabilities: [40] Power Management version 2
        Capabilities: [50] Message Signalled Interrupts: Mask- 64bit+ Queue=0/0 Enable-
        Capabilities: [60] Express Legacy Endpoint, MSI 00
        Capabilities: [100] Advanced Error Reporting <?>
        Kernel driver in use: arcmsr
        Kernel modules: arcmsr

Postup zprovoznění pod Linuxem

ovladač je ve vanila jádře:
    arcmsr.ko
.
.
.
--- SCSI low-level drivers
 <*>  ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter

Poznámka

- Sice má jen 2 porty, ale je to plnokrevný HW RAID s pořadným BIOSem a management tool'ama.
  Více na:
    http://www.areca.com.tw/products/2ports.htm
  Driver/Utility:
    ftp://ftp.areca.com.tw/RaidCards/AP_Drivers/Linux/
- Teprve ho testuju.
- Přidal jsem ho k pci-ids:
    http://pci-ids.ucw.cz/iii/?i=17d3

$ smartctl -a /dev/sdb
smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

Device: Areca    ARC-1200-VOL#00  Version: R001
Serial number: 0000003109736019
Device type: disk
Transport protocol: Fibre channel (FCP-2)
Local Time is: Wed May  7 07:56:36 2008 CEST
Device supports SMART and is Enabled
Temperature Warning Disabled or Not Supported
SMART Health Status: OK

Current Drive Temperature:     30 C
Drive Trip Temperature:        25 C
Manufactured in week 30 of year 2002
Recommended maximum start stop count:  4278190080 times
Current start stop count:      256 times
Elements in grown defect list: 0

Error counter log:
           Errors Corrected by           Total   Correction     Gigabytes    Total
               ECC          rereads/    errors   algorithm      processed    uncorrected
           fast | delayed   rewrites  corrected  invocations   [10^9 bytes]  errors
read:          0        0         0         0          0          0.000           0
write:         0        0         0         0          0          0.000           0

Non-medium error count:        0
Device does not support Self Test logging

Dokument vytvořil: Tomas Mazanec, 30.4.2008 14:40 | Poslední úprava: Tomas Mazanec, 27.2.2011 15:09 | Historie změn | Zobrazeno: 1023×