NETDEV WATCHDOG: eth0: transmit timed out tg3: eth0: transmit timed out, resetting tg3: DEBUG: MAC_TX_STATUS[00000018] MAC_RX_STATUS[00000000] tg3: DEBUG: RDMAC_STATUS[00000000] WDMAC_STATUS[00000000] tg3: tg3_stop_block timed out, ofs=2c00 enable_bit=2 tg3: tg3_stop_block timed out, ofs=1400 enable_bit=2 tg3: tg3_stop_block timed out, ofs=c00 enable_bit=2 PM: Writing back config space on device 0000:03:00.0 at offset 1 (was 100406, writing 100006) tg3: eth0: Link is down. PM: Writing back config space on device 0000:03:00.0 at offset 1 (was 100406, writing 100006) tg3: eth0: Link is up at 100 Mbps, full duplex. tg3: eth0: Flow control is off for TX and off for RX.Je to pripojene do Cisco catalyst 2950 switchu. Robilo to aj ked bol port na switchi autonegotiation, aj ked je dane na pevno 100MBit FD. Takyto problem to zacalo robit po cca 5-6dni prevadzky, dovtedy ziaden naznak problemu. Kde by mohol byt problem? Na forach som cital ze niektore cisco switche maju dusevny problem s broadcom sietovkami, a ze pomoze nastavit port na switch na pevno na nejaku rychlost, ale tu to nepomohlo:(. Dik za kazdu radu.
Upozorňuji že v kernelu 2.6.21.7 je ovladač TG3 verze 3.75,
ve kterém tato chyba ještě není odstraněná. Takže budeš potřebovat novější kernel, ale znáš to
- většina modulů, které nejsou přímo v distribuci kernelu, je min. o 2 verze pozadu...
Zkus tedy raději
ethtool -K eth0 tso off
Nebo místo síťovky broadcom a TG3 použij nějaký Intel s driverem E1000.