/dev/VolGroup00/LogVol00 / ext3 defaults 1 1 LABEL=/boot /boot ext3 defaults 1 2 tmpfs /dev/shm tmpfs defaults 0 0 devpts /dev/pts devpts gid=5,mode=620 0 0 sysfs /sys sysfs defaults 0 0 proc /proc proc defaults 0 0 /dev/VolGroup00/LogVol01 swap swap defaults 0 0DMESG:
ioc0: SAS1068: Capabilities={Initiator} scsi0 : ioc0: LSISAS1068, FwRev=00033200h, Ports=1, MaxQ=511, IRQ=233 Vendor: HP Model: DF072A8B56 Rev: HPD3 Type: Direct-Access ANSI SCSI revision: 05 Vendor: HP Model: DF072A8B56 Rev: HPD3 Type: Direct-Access ANSI SCSI revision: 05 Vendor: LSILOGIC Model: Logical Volume Rev: 3000 Type: Direct-Access ANSI SCSI revision: 02 SCSI device sda: 142577664 512-byte hdwr sectors (73000 MB) sda: Write Protect is off sda: Mode Sense: 03 00 00 08 SCSI device sda: drive cache: write through SCSI device sda: 142577664 512-byte hdwr sectors (73000 MB) sda: Write Protect is off sda: Mode Sense: 03 00 00 08 SCSI device sda: drive cache: write through sda: sda1 sda2 sd 0:1:0:0: Attached scsi disk sda------------------------------------------------------------------------- Rozhodli jsme se pridat dalsi mirror z 2x147GB disku. Pomoci LSI BIOSu jsme pridali new array. Bez problemu Start systemu probihal v poradku do okamziku kdy se do konzole zacalo vypisovat:
Apr 25 14:21:28 v1 kernel: mptbase: ioc0: LogInfo(0x31110a00): Originator={PL}, Code={Reset}, SubCode(0x0a00) Apr 25 14:21:28 v1 kernel: mptbase: ioc0: LogInfo(0x31120400): Originator={PL}, Code={Abort}, SubCode(0x0400) Apr 25 14:21:29 v1 last message repeated 37 times Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=f6ec4380) Apr 25 14:21:29 v1 kernel: sd 0:1:1:0: Apr 25 14:21:29 v1 kernel: command: Write(10): 2a 00 02 bf 55 8d 00 01 40 00 Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: task abort: FAILED (sc=f6ec4380) Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=c2b3b080) Apr 25 14:21:29 v1 kernel: sd 0:1:1:0: Apr 25 14:21:29 v1 kernel: command: Write(10): 2a 00 02 b7 52 f5 00 00 08 00 Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: task abort: FAILED (sc=c2b3b080) Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=c2b50500) Apr 25 14:21:29 v1 kernel: sd 0:1:1:0: Apr 25 14:21:29 v1 kernel: command: Write(10): 2a 00 02 b7 53 0d 00 00 10 00 Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: task abort: FAILED (sc=c2b50500) Apr 25 14:21:29 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=f62d2e00) Apr 25 14:21:29 v1 kernel: sd 0:1:1:0: Apr 25 14:21:29 v1 kernel: command: Write(10): 2a 00 02 bf 77 0d 00 00 08 00 Apr 25 14:21:30 v1 kernel: mptscsih: ioc0: task abort: FAILED (sc=f62d2e00) Apr 25 14:21:30 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=f6eb9200) Apr 25 14:21:30 v1 kernel: sd 0:1:1:0: Apr 25 14:21:30 v1 kernel: command: Write(10): 2a 00 02 bf 77 1d 00 00 38 00 Apr 25 14:21:30 v1 kernel: mptscsih: ioc0: task abort: FAILED (sc=f6eb9200) Apr 25 14:21:30 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=c2b50680) Apr 25 14:21:30 v1 kernel: sd 0:1:1:0: Apr 25 14:21:30 v1 kernel: command: Write(10): 2a 00 02 c0 f2 e5 00 00 08 00 Apr 25 14:21:31 v1 kernel: mptscsih: ioc0: task abort: FAILED (sc=c2b50680) Apr 25 14:21:31 v1 kernel: mptscsih: ioc0: attempting task abort! (sc=f6eb9680)Server uz nenabehl v poradku. Po rebootu opet stejna situace. Po vyjmuti disku a ponechani konfigurovaneho druheho pole server nabehl zpet do funkcniho stavu po kontrole fs. Co je spatne? Jak pridat druhy mirror do systemu?
rx2660 with 8-port SAS controller and IR configured rx3600 with 8-port SAS controller and IR configured rx6600 with 8-port SAS controller and IR configuredmozno aj dalsich.
This only happens to one or two physical disks when one or two IR volumes are configured and the IR LUN numbers match the bay number of physical disks. For example, if one IR is configured using disks in bays 7 & 8 and is assigned LUN# 5 and then firmware is upgraded to 1.23.33, the physical disk in bay 5 becomes non-responsive and cannot be accessed. An additional IR can cause a second disk to be inaccessible if the IRs logical number happens to correspond to the bay number of the physical disk. So, if the second IR is assigned LUN# 4, then the disk in bay 4 will not be accessible.Prejavuje sa u vas toto ?