root@dan:~# lspci 00:00.0 Host bridge: Broadcom CMIC-WS Host Bridge (GC-LE chipset) (rev 13) 00:00.1 Host bridge: Broadcom CMIC-WS Host Bridge (GC-LE chipset) 00:00.2 Host bridge: Broadcom CMIC-LE 00:03.0 VGA compatible controller: ATI Technologies Inc Rage XL (rev 27) 00:04.0 System peripheral: Compaq Computer Corporation Integrated Lights Out Controller (rev 01) 00:04.2 System peripheral: Compaq Computer Corporation Integrated Lights Out Processor (rev 01) 00:0f.0 ISA bridge: Broadcom CSB5 South Bridge (rev 93) 00:0f.1 IDE interface: Broadcom CSB5 IDE Controller (rev 93) 00:0f.2 USB Controller: Broadcom OSB4/CSB5 OHCI USB Controller (rev 05) 00:0f.3 Host bridge: Broadcom CSB5 LPC bridge 00:10.0 Host bridge: Broadcom CIOB-X2 PCI-X I/O Bridge (rev 05) 00:10.2 Host bridge: Broadcom CIOB-X2 PCI-X I/O Bridge (rev 05) 00:11.0 Host bridge: Broadcom CIOB-X2 PCI-X I/O Bridge (rev 05) 00:11.2 Host bridge: Broadcom CIOB-X2 PCI-X I/O Bridge (rev 05) 01:03.0 RAID bus controller: Compaq Computer Corporation Smart Array 5i/532 (rev 01) 02:01.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5703X Gigabit Ethernet (rev 02) 02:02.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5703X Gigabit Ethernet (rev 02) 03:01.0 RAID bus controller: Silicon Image, Inc. SiI 3114 [SATALink/SATARaid] Serial ATA Controller (rev 02) 06:1e.0 PCI Hot-plug controller: Compaq Computer Corporation PCI Hotplug Controller (rev 14)
ASR to moze byt, hlavne ak je velky vyhul na cpu alebo i/o, najdes v logoch ILO karty popripade System Management Homepage (za predpokladu ze mas nainstalovany PSP -> proliant support pack)
dalej skontroluj stav Smartarrayu, tiez moze byt pricinou (hlavne ak je cache zalohovana baterkou a ta je v srackach)
D.
PSP je mnozstvo toolov a demonov, ktorymi sa managuje kontroluje HP box. t.j. jeho teploty otacky ventilatorov stav radica a co ja viem co este
najdes ho tu
nakolko HP nepodporuje *deb distra stiahni si pre nejaky redhat, ked to rozbalis budes mat hrbu *.rpm suborov.
Alienom potom spravis z *.rpm *.deb balicky a normalne ich nainstalujes
Nepotrebujes ich instalovat vsetky
Mne napriklad stacia tieto:
ii hp-health 8.2.5.47-26 hp System Health Application and Command line Utility Package
ii hp-ilo 8.3.0-119 HP iLO Channel Interface Driver
ii hp-smh-templates 8.2.5.6-6 HP System Management Homepage Templates
ii hp-snmp-agents 8.2.5.20-11 Insight Management SNMP Agents for HP ProLiant Systems
ii hpacucli 8.28-13.0.10-10 HP Command Line Array Configuration Utility
rc hpasm 7.8.0-100.etch26 hp System Health Application and Insight Management Agents Package
ii hponcfg 2.2.0-6 hponcfg - An RILOE II/iLo online configuration utility
ii hpsmh 3.0.2-75 HP System Management Homepage
D.
hele, jak poznam, ze je to je zalohovano baterkou a ze je v haji? (do serverovny se chystam ve ct v noci)dalej skontroluj stav Smartarrayu, tiez moze byt pricinou (hlavne ak je cache zalohovana baterkou a ta je v srackach)
D.
prikaz hpacucli spusti management tool pre smartarray radic
a potom napr takto
root@h0stn4m3:> hpacucli
HP Array Configuration Utility CLI 8.28-13.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> controller all show
Smart Array 5i in Slot 0 (Embedded)
=> controller slot=0 show
Smart Array 5i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Chassis Slot:
Hardware Revision: Rev B
Firmware Version: 2.58
Rebuild Priority: Low
Expand Priority: Low
Surface Scan Delay: 15 secs
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Accelerator Ratio: 100% Read / 0% Write
Read Cache Size: 48 MB
Write Cache Size: 0 MB
Total Cache Size: 48 MB
No-Battery Write Cache: Disabled
Battery/Capacitor Count: 0
SATA NCQ Supported: False
=>
root@dan:~# hpacucli ctrl all show config FIRMWARE UPGRADE REQUIRED: A firmware update is recommended for this controller to prevent rare potential data write errors on a RAID 1 or RAID 1+0 volume in a scenario of concurrent background surface analysis and I/O write operations. Please refer to Customer Advisory c01587778 which can be found at hp.com. Smart Array 5i in Slot 0 (Embedded) array A (Parallel SCSI, Unused Space: 0 MB) logicaldrive 1 (67.8 GB, RAID 0, OK) physicaldrive 2:0 (port 2:id 0 , Parallel SCSI, 72.8 GB, OK) array B (Parallel SCSI, Unused Space: 0 MB) logicaldrive 2 (67.8 GB, RAID 0, OK) physicaldrive 2:1 (port 2:id 1 , Parallel SCSI, 72.8 GB, OK)
root@dan:/tmp# grep -i batt cucli.txt Cache Battery Count 0 (0x00) Battery PIC Revision 0x00 Battery Count 0 (0x0000) Battery Status 0x0000 Failed Batteries 0 (0x0000) Non Battery Backed Memory Size 48 MB (0x0030) Installed Batteries 0x0000 Detailed Battery Status All Zeroes (16 x [0x00])