Portál AbcLinuxu, 12. května 2025 21:54
# hpacucli controller all show status Smart Array E200 in Slot 2 Controller Status: OK Cache Status: OK Battery Status: OK # hpacucli controller slot=2 pd all show status physicaldrive 1:1 (box 1:bay 1, 72 GB): OK physicaldrive 1:2 (box 1:bay 2, 72 GB): OK
arrayprobe -r
a arrayprobe -o
. SMART dáta potom cez smartctl -a /dev/cciss/c0d0 -d cciss,0
, kde posledný parameter je číslo disku - cciss,0, cciss,1, cciss,2, atď. Manažovať v zmysle pridávať disky a meniť polia - to som nepotreboval, tak neviem.
# smartctl -a /dev/cciss/c0d0 -d cciss,1 smartctl 5.40 2010-07-12 r3124 [x86_64-unknown-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net Serial number: WD-WXLX08124043 Device type: disk Local Time is: Sun May 13 02:21:58 2012 CEST Device supports SMART and is Enabled Temperature Warning Disabled or Not Supported SMART Health Status: OK Current Drive Temperature: 34 C Read defect list: asked for grown list but didn't get it Error Counter logging not supported [GLTSD (Global Logging Target Save Disable) set. Enable Save with '-S on'] No self-tests have been logged Long (extended) Self Test duration: 7380 seconds [123.0 minutes]Tak tuto vela toho nevidim :(.