LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05)
# MegaCli64 -AdpBbuCmd -GetBbuStatus -a0 -NoLog | egrep -i 'charge|battery'
BBU status for Adapter: 0
BatteryType: iBBU
Voltage: 4054 mV
Current: 48 mA
Temperature: 33 C
Battery State: Degraded(Need Attention)
A manual learn is required.
BBU Firmware Status:
Charging Status : Charging
Voltage : OK
Temperature : OK
Learn Cycle Requested : Yes
Learn Cycle Active : No
Learn Cycle Status : OK
Learn Cycle Timeout : No
I2c Errors Detected : No
Battery Pack Missing : No
Battery Replacement required : No
Remaining Capacity Low : No
Periodic Learn Required : No
Transparent Learn : No
No space to cache offload : No
Pack is about to fail & should be replaced : No
Cache Offload premium feature required : No
Module microcode update required : No
GasGuageStatus:
Fully Discharged : No
Fully Charged : No
Discharging : No
Initialized : Yes
Remaining Time Alarm : No
Discharge Terminated : No
Over Temperature : No
Charging Terminated : No
Over Charged : No
Relative State of Charge: 90 %
Charger System State: 49168
Charger System Ctrl: 0
Charging current: 512 mA
Absolute state of charge: 90 %
Max Error: 12 %
Exit Code: 0x00
server je stale zapnuty, ale baterie je nabita pouze na 89 %. Pise ze "A manual learn is required", ale jak na to?
MegaCli64 -AdpBbuCmd -BbuLearn -a0
Adapter 0: BBU Learn Failed
Exit Code: 0x01
Muzete mi prosim poradit, co mi to vlastne rika a jak postupovat? Je baterie vadna a musim ji vymenit?
Dekuji.