Portál AbcLinuxu, 8. května 2025 18:18
Řešení dotazu:
/1 N1Ktery provede clear SMART. 50c
This condition was introduced by a firmware issue that sets the drive event log to an invalid location causing the drive to become inaccessible. The firmware issue is that the end boundary of the event log circular buffer (320) was set incorrectly. During Event Log initialization, the boundary condition that defines the end of the Event Log is off by one. During power up, if the Event Log counter is at entry 320, or a multiple of (320 + x*256), and if a particular data pattern (dependent on the type of tester used during the drive manufacturing test process) had been present in the reserved-area system tracks when the drive's reserved-area file system was created during manufacturing, firmware will increment the Event Log pointer past the end of the event log data structure.
Tiskni
Sdílej:
ISSN 1214-1267, (c) 1999-2007 Stickfish s.r.o.