Portál AbcLinuxu, 8. května 2025 11:26
htpc hurvajs # smartctl -a -i /dev/sdd smartctl 6.3 2014-07-26 r3976 [x86_64-linux-3.18.5-gentoo] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Black Device Model: WDC WD2002FAEX-007BA0 Serial Number: WD-WMAY01473579 LU WWN Device Id: 5 0014ee 6ab9fa1ef Firmware Version: 05.01D05 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Fri Feb 6 07:39:04 2015 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 121) The previous self-test completed having the read element of the test failed. Total time to complete Offline data collection: (28980) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 295) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3037) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 253 253 021 Pre-fail Always - 8858 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1617 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 088 088 000 Old_age Always - 9390 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1600 192 Power-Off_Retract_Count 0x0032 199 199 000 Old_age Always - 901 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 715 194 Temperature_Celsius 0x0022 117 085 000 Old_age Always - 35 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 1 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 1 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed: read failure 90% 9390 3901101166 # 2 Extended offline Completed: read failure 90% 9384 3901101166 # 3 Extended offline Completed: read failure 90% 9381 3901101166 # 4 Short offline Completed: read failure 90% 9381 3901101166 # 5 Extended offline Completed: read failure 90% 8935 3901101166 # 6 Short offline Completed: read failure 90% 8934 3901101166 # 7 Short offline Completed: read failure 90% 8551 3901101166 # 8 Short offline Completed: read failure 90% 8551 3901101166 # 9 Extended offline Completed: read failure 90% 8478 3901101166 #10 Extended offline Completed: read failure 90% 8478 3901101166 #11 Short offline Completed: read failure 90% 8478 3901101166 #12 Short offline Completed: read failure 90% 8478 3901101166 #13 Short offline Completed: read failure 90% 8477 3901101166 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
Tiskni
Sdílej:
ISSN 1214-1267, (c) 1999-2007 Stickfish s.r.o.